Silent X-Stream™ Cabinet Enclosure Cooler For Electronic Control Panel Coolers
Silent X-Stream™ Cabinet Enclosure Cooler (Panel Coolers / Cooling Air Conditioner)- Frigid-X™ - Sizing Specifications:
Contact Nex Flow™ for assistance in sizing cabinet enclosure cooler - Frigid-X™ series.
Below see Sizing Specifications.
MODEL NO. |
VERSION |
BTU/Hr. cooling* |
61008A-X |
NEMA Type 12 (IP-52) Continuous Operation |
580 |
61015A-X |
NEMA Type 12 (IP-52) Continuous Operation |
1100 |
61025A-X |
NEMA Type 12 (IP-52) Continuous Operation |
1800 |
61030A-X |
NEMA Type 12 (IP-52) Continuous Operation |
2100 |
61040A-X |
NEMA Type 12 (IP-52) Continuous Operation |
2900 |
63008A-X |
NEMA Type 12 (IP-52) on-off control |
580 |
63015A-X |
NEMA Type 12 (IP-52) on-off control |
1100 |
63025A-X |
NEMA Type 12 (IP-52) on-off control |
1800 |
63030A-X |
NEMA Type 12 (IP-52) on-off control |
2100 |
63040A-X |
NEMA Type 12 (IP-52) on-off control |
2900 |
61008R-X |
NEMA Type 3R (IP-14) Continuous Operation |
|
61015R-X |
NEMA Type 3R (IP-14) Continuous Operation |
1100 |
61025R-X |
NEMA Type 3R (IP-14) Continuous Operation |
1800 |
61030R-X |
NEMA Type 3R (IP-14) Continuous Operation |
2100 |
61040R-X |
NEMA Type 3R (IP-14) Continuous Operation |
2900 |
63008X-X |
NEMA Type 3R (IP-14) on-off control |
580 |
63015X-X |
NEMA Type 3R (IP-14) on-off control |
1100 |
63025X-X |
NEMA Type 3R (IP-14) on-off control |
21800 |
63030X-X |
NEMA Type 3R (IP-14) on-off control |
2100 |
63040X-X |
NEMA Type 3R (IP-14) on-off control |
2900 |
61108X-X |
NEMA Type 4-4X (IP-56) Continuous Operation |
580 |
61115X-X |
NEMA Type 4-4X (IP-56) Continuous Operation |
1100 |
61125X-X |
NEMA Type 4-4X (IP-56) Continuous Operation |
1800 |
61130X-X |
NEMA Type 4-4X (IP-56) Continuous Operation |
2100 |
61140X-X |
NEMA Type 4-4X (IP-56) Continuous Operation |
2900 |
63108X-X |
NEMA Type 4-4X (IP-56) on-off control |
580 |
63115X-X |
NEMA Type 4-4X (IP-56) on-off control |
1100 |
63125X-X |
NEMA Type 4-4X (IP-56) on-off control |
21800 |
63130X-X |
NEMA Type 4-4X (IP-56) on-off control |
2100 |
63140X-X |
NEMA Type 4-4X (IP-56) on-off control |
2900 |
*Cooling effect based on 95º F temperature inside cabinet, 100 PSIG (6.9 BAR) compressor inlet pressure, and 70ºF (21ºC) inlet temperature.
BTU/hr. figures rounded to nearest 100 BTU/hr (1 WATT).
All Continuous Operation models include the cooling unit, filter with auto drain and cold air distribution kit.
All On-Off control units include the cooling unit, filter with auto drain, cold air distribution kit, solenoid valve and thermostat.