Standard Air Amplifier
Air mover Air Amplifier - Compressed Air Consumption:
(Based on gap of 0.002” (.05mm)
Compressed Air Consumption in SCFM (SLPM)
Inlet Pressure |
AM10 |
AM20 |
AM40 |
AM75 |
AM125 |
20 PSIG (1.4 BAR) |
2.2 (62.3) |
4.3 (121.8) |
8.0 (226.5) |
16.5 (467.2) |
65.0 (1840.6) |
40 PSIG (2.8 BAR) |
3.4 (96.3) |
6.1 (172.7) |
11.3 (320.0) |
23.2 (657.0) |
90.0 (2548.5) |
60 PSIG (4.1 BAR) |
4.3 (121.8) |
7.5 (212.4) |
15.0 (424.8) |
29.7 (841.0) |
119.5 (3383.9) |
80 PSIG (5.5 BAR) |
4.9 (138.8) |
9.3 (263.3) |
19.3 (546.5) |
37.0 (1047.7) |
137.5 (3893.6) |
100 PSIG (6.9 BAR) |
5.8 (164.2) |
11.0 (311.5) |
25.1 (710.8) |
44.0 (1245.9) |
150.0 (4247.5) |
120 PSIG (8.4 BAR) |
6.1 (172.7) |
11.8 (334.1) |
26.0 (736.2) |
47.0 (1330.9) |
152.0 (4304.2) |
Air mover Air Amplifier - Ducting:
Both the inlet (vacuum intake) and discharge ends of the unit may be ducted for light material and fume conveying applications. Care must be taken to avoid unnecessary restrictions that will cause back pressure or suction resistance that will reduce performance levels. Keep back pressure and resistance to under 2" of water column.